DIN Rail Switch (AD10)
230 VAC - 50 Hz - 16A LOAD RATING
Key Features
Install at the breaker panel/fuse box for X-10 control of branch lighting circuits or
appliances rated up to 16 A- ideal for aircon, heaters etc.
Works with X-10 controller and standard latched or momentary action wall switches -
including "designer" wall switches.
Benefits
The X-10 DIN rail switch is a remote
controlled relay. Discretly installed at the
junction box, it switches hard-wired
circuits with several switches (e.g.
hallway lighting).
The internal relay can be tripped either
by external latched or momentary action
wall switches or by an X-10 controller.
The AD10 responds to "standard" X-10
that is: "All units off" from any X-10
controller set to its house code regard-
less of unit code or alternatively indi-
vidual unit control by "On" and "Off".
When the relay is energized, the LED
above the slide switch is illuminated.
Slide switch:
Position 0: the connected load is
switched off permanently and cannot be
switched on by the wall switches or an X-
10 controller.
Position 1: the connected load is
switched on permanently and cannot be
switched off by the wall switches or an X-
10 controller.
Position auto: the connected load can be
switch by the wall switches or an X-10
controller.
Terminal 1 is designed for toggle
switches: the relay picks up when phase
is present and releases when there is
no voltage at the terminal.
Terminal 2 is designed for pulse con-
tacts : each time phase is applied the
relay switches.
Technical data
Supply voltage: 230 V +10% -15% 50 Hz
Supply current : 20 mA capacitive
Making capacity: 2000 W ( incandescent lamp)
3 A (motors)
16 A (resistive loads)
EMC emission: according to EN 50081-1
EMC immunity: according to EN 50082-1
Electrical safety: according to EN 60950 and EN 60065
Signal sensitivity: 15 mVpp min 50 mVpp max at 120 kHz
Input impedance: 180 Ohms (L - N) at 120 kHz
Connections: screw type terminals for phase, neutral, switched
phase, control 1 and 2.
Ambient temperature: - 10° C to + 40° C (operation)
- 20° C to + 70° C (storage)
Typical applications
This unit can replace any pulse contact relay that is commonly used for multi
switched hall and entry lighting. In discrete locations, eg kitchen lighting, you
may prefer to install the AD10 in a small sub-junction box.