FUNCTION ADDRESSES
Function: Address: With ref. address A1: With ref. address B3:
Alarm light [HC+[UC] A1 B3
All lights [UC] A B
Status Indicator [HC] + [UC+1] A2 B4
Lifestyle [HC] + [UC+2] [UC+3] A3 and A4 B5 and B6
External Siren [HC+1] + [UC] B1 C3
Thermostat Setback [HC+1] + [UC+1] B2 C4
CONTROL INDIVIDUAL MODULES WITH THE SC2200 BASE STATION
You can also control Marmitek X-10 Home Automation modules from the keyboard of the SC2200 base station. Key in the unit code on the keyboard
(for 15: key in 1 and 5). You’ll hear a confirmation beep after each key press. Press the UNIT ON button to switch a module on or press UNIT OFF to switch
the module off.
CONTROL ALL MODULES WITH THE SC2200 BASE STATION
ALL LIGHTS ON: All lamp modules with the House Code of the base station will come on
ALL LIGHTS OFF: All modules with the House Code of the base station will go out
CONTROLLING INDIVIDUAL MODULES WITH SH624/1 SYSTEM REMOTE CONTROL (REFER TO 5.1).
26 MARMITEK
AVAILABLE FUNCTIONS
ALARM LIGHT
This Home Automation module will be switched
on during the arm delay of the security system.
As soon as the system arms, the module is
switched off. This module can also be controlled
by pressing the Light On – Light Off keys of the
KR10/1 Key Fob Remote. Now there is no need to
arrive home in the dark anymore, or leave on
lights in the house when you are going away.
During an alarm, all lamp modules having the same
House Code as the base station (in our example
with base address A1, all lamp modules with House
Code A) will be switched on and off (flashing)
during the alarm time of 4 minutes. All appliance
modules with House Code A will be switched off.
STATUS INDICATION
This Home Automation module will be switched
on as soon as you arm the system. The module
will be switched of as soon as the system is
disarmed. Gives you the status of your security
system being in armed or disarmed mode.
LIFESTYLE FUNCTION
Modules will be switched on and off to simulate
your presence. (refer to 6.9).
EXTERNAL SIREN
These will be activated during an alarm and will
be automatically switched off after 4 minutes.
You now can place multiple sirens without
installing extra cables.
THERMOSTAT SETBACK
Module will be switched off as soon as the system
is armed and switched on as soon as the system is
disarmed. Can be used to set back the
thermostat or switch off equipment automatically
when you leave the house. Will be used in
combination with scenes/macro’s (wake up, leave,
come home, sleep, etc.) of the Marmitek X-10
CM11 Computer Interface. For more information
ask you dealer or look at our website:
www.marmitek.com.
To control the functions as described above, the
code setting on the base station and Home
Automation modules are used. These codes
consist of a House Code (HC: letter A-P) and a
Unit Code (UC: number 1-16).
The reference address has to be set at the base
station. The factory default is A1. The A is the HC
and the one is the UC. By choosing the reference
address, the addresses of the 5 above listed
functions are fixed.
The alarm light (function 1) gets the same
address as the reference address of the base
station. In this example you have to set the
address of the (lamp) module to A1 also.
The address for status indication (function 2) results
from increasing the reference address by 1. In case
of the reference address being A1, this becomes
A2. A more general description is [HC] + [UC+1].
The table below lists all functions in this way.
The addresses used for the Lifestyle function
(function 3) result from increasing the reference
address with 2 and 3 respectively. When A1 is the
reference address, the Lifestyle addresses will
become A3 and A4.
A module on another House Code can activate an
External Siren (function 4). In this way you can avoid
activating this siren by mistake using a remote
control. The address results from using the next
letter of the House Code. A1 being the reference
address, this results in B1 for external sirens.
The thermostat setback address results from
using the next letter of the House Code as well as
increasing the Unit Code by 1. Using A1 as the
reference address, the thermostat setback
address becomes B2.